Edge board made of wood fibre material for stronger and accurate edging, to be laid along the edge insulation strips. 5 mm wood fibre layer on underside to reduce structure-borne noise and compensate for minor surface unevenness. Mandatory for all installation variants with insulation mat and directly laid. Recommended for installations with dry screed.
Dimensions (L x W x H): 1000 x 45 x 16 mm
|
|
|
Load distribution and insulation mat, in conjunction with TECEfloor universal panel UP 16/12, for tiles and laminate. Polyester fibre board made of aluminium-clad polyester fleece and thermoplastic binder; consequently, high tear resistance and compression strength, movable loads up to 2 kN/m², point loads up to 2 kN. Thermal conductivity: 0.2 W/mK Weight: approx. 5.2 kg/m²
Tile formats - min. size 10 x 10 cm or 100 cm²
- max. size 80 x 80 cm
- min. thickness (natural stone) 10 mm
Joint size
- min. 3 mm up to tile size 30 x 30 cm
- min. 4 mm up to tile size 40 x 40 cm
- min. 5 mm up to tile size 80 x 80 cm
Field size
- up to max. 60 m², length/width ratio max. 2:1
Dimensions (L x W x H): 1150 x 600 x 5 (+0.5) mm
|
|
|
Adhesive tape to glue insulation mat edges when laying tiles.
|
|
|
Dispersion fixing, for gluing the universal panels to the subsurface (only when laid directly) and for gluing the insulation mat to the universal panel, 10 kg container.
|
|
|
Pipe base plate for installation of underfloor heating according to construction type B (laying pipe within the insulation layer under screed). Allows use with standard dry screed elements (Knauf, Fermacell, Rigips, etc.) as well as wet screed (cement screed, flow screed). Made of expanded polystyrene hard foam (EPS), with pipe layout channels for incorporating TECEfloor heat conduction profiles and TECEfloor underfloor heating pipes 16 x 2 mm. Can be laid in single as well double meander, HBCD-free.
Material: expanded polystyrene (EPS 035 DEO), building material class E Thermal conductivity: 0.035 W/mK, R = 0,77 m²K/W Compression strength 150 kPa at 10 % compression in accordance with EN 826 Spacing: VA 150, VA 300 (single and double meander) Dimensions (L x W x H): 1150 x 750 x 30 mm
|
|
|
Heat conduction profile for mounting on the TECEfloor dry-wall panel TP 30/16. For uniform heat distribution by heating pipe over the dry screed plate. For taking TECEfloor underfloor heating pipes 16 x 2 mm. With predetermined breaking points for separation without tools.
Dimensions (L x W x H): 1000 x 132 x 0.4 mm/0.45 mm Material requirements: approx. 6 pcs./m² (VA 15)
|
|
|
Hot cutter with U-shaped cutting blade (dimension 12 and dimension 16) for cutting out inlet guides in EPS compensating elements, connection voltage 230 V.
|
|
|
U-shaped cutting blade for TECEfloor heat cutter, for cutting the inlet guides in the EPS combination element UP 16/12.
|
|
|
Plastic-coated board binders to fix pipes on and join backerboards together. Length: 120 mm.
|
|
|
Tacking tool to quickly and precisely attach collated TECEfloor pipe clips 17 mm to a 3 mm TECEfloor backerboard.
|