Insulation made of EPS DES sg BS50-SD20-CP2, WLG 040, Rλ = 0.75 m²K/W, coated with a tear-resistant strip woven film, moveable load max. 5 kN/m², impact sound improvement 29 dB (to DIN 4109-34: 2016-07 with 60 mm total screed thickness or 45 mm pipe overlap), HBCD-free.
|
|
|
Insulation made of EPS DES sm BS50-SD15-CP3, WLG 045, Rλ = 0.67 m²K/W, class E/B2, coated with a tear-resistant strip woven film, moveable load max. 4 kN/m², impact sound improvement 31 dB (to DIN 4109-34: 216-07 with 60 mm total screed thickness or 45 mm pipe overlap), HBCD-free.
|
|
|
2 mm thick PP hollow chamber sheet for universal laying on insulation on-site such as suitable mineral wool, EPS or PUR insulation. Suitable for the secure fixture of TECEfloor underfloor heating pipes using TECEfloor tacking pins T8, T6 or 10plus. Rolls L x W: 30 m x 1.0 m (30 m²)
|
|
|
Adhesive tape to create a waterproof screed form by sticking on the stapled insulation joints.
|
|
|
Tape unwinder for efficient use of adhesive tape.
|
|
|
Tacking tool specially designed for extra-wide tacking pins T8 extra (8 mm). The precision-made tools are distinguished by their excellent reliability. Incl. stand, weight and inspection opening.
Not suitable for conventional 6 mm tacking pins.
|
|
|
Extra-wide tacking pins with 8 mm wide clip for better fixing and guiding of heating pipes, particularly in floor areas. Tacking pin with special anchor, very good foil penetration, low damage to strip woven film and improved hold with 45° angle of pull (curves). Optimised for EPS insulation, not suitable for PUR insulation.
Cannot be used with standard tacking tools!
|
|
|
Standard tacking tool for conventional 6 mm tacking pins of length 40 mm or 55 mm. These precision-made tools are distinguished by their excellent reliability. Incl. stand, weight and inspection opening.
|
|
|
Standard tacking pins, heat-applied, can be used with many conventional tacking tools.
|
|
|
Thermal insulation board made of expanded polystyrene rigid foam EPS DEO dh BS200-CS(10)150 according to EN 13163, laminated with a tear-resistant ribbon fabric foil, with 5 cm grid imprint, as screed moisture protection according to DIN 18560 and for secure fixing of the heating pipes using TECEfloor tacker pins 10plus. Panel thickness: 10 mm, thermal conductivity: 0.034 W/mK (WLS 040), thermal resistance: 0.29 m²K/W, compression strength at 10% compression 150 kPa, fire behaviour: E (B2), panel dimension: 2.0 x 1.0 m (2 m²)
|